RN1-10 High-Voltage Current Limiting Fuse

Table of Contents

Introduction to RN1-10 High-Voltage Current Limiting Fuse

The RN1-10 High-Voltage Current Limiting Fuse is a critical component in electrical systems, designed to protect circuits from overcurrents and short circuits. Engineered for reliability and precision, this fuse ensures safe operation in high-voltage environments up to 35kV. Its advanced current-limiting technology minimizes damage to equipment, making it indispensable for power distribution networks, industrial plants, and substations.

RN1-10 High-Voltage Current Limiting Fuse

Key Features & Benefits

  • High Breaking Capacity: Interrupts fault currents up to 40kA (effective value).
  • Versatile Voltage Ratings: Compatible with 3kV, 6kV, 10kV, and 35kV systems.
  • Robust Construction: Sealed porcelain tube filled with quartz sand for arc suppression.
  • Precision Protection: Tailored for specific current ratings (20A to 400A).
  • Easy Installation: Standardized dimensions for seamless integration.

Technical Specifications

Table 1: Electrical Performance Parameters

Rated Voltage (kV)Rated Current (A)Max Breaking Current (kA, eff.)Min Breaking Current (Multiple of Rated Current)Three-Phase Max Cut-Off Capacity (MVA)
320–400401.38–15.7
620–2001.31.38.5–17
1020–2001.31.310–21
357.5–401.31.310–27

Table 2: Structural Components

ComponentMaterial/Function
Fuse PipePorcelain tube housing fuse wire and quartz sand for arc quenching.
Fuse WirePrecision-calibrated for specific current ratings (rolled or suspended design).
Quartz SandEnhances arc extinction and thermal stability.
Indicator SystemSpring-loaded mechanism with visual indicator for fault detection.

Note:

  • For ≤7.5A @35kV, fuse wire is rolled on a porcelain core (Chart 2a).
  • For >7.5A, fuse wire is suspended within the porcelain tube (Chart 3).
RN1/RN3“An-second” characteristic curve

Dimensions & Mounting

Table 3: RN1-10 Series Dimensions (mm)

Product TypeRated Voltage (kV)Fuse Current (A)AaLH1Hb
RN1-6/262310500550125235108
RN1-10/201020410600650
RN1-3/2003200270400450350108
RN1-10/20010200460600650108

(Full dimensional data available upon request)


Applications

The RN1-10 fuse is ideal for:

  • Power Transformers: Overcurrent protection in substations.
  • Motor Circuits: Safeguarding industrial motors from short circuits.
  • HV Distribution Lines: Ensuring grid reliability.
  • Renewable Energy Systems: Integration into solar/wind farms.

Why Choose RN1-10?

  1. Superior Safety: Quartz sand filling ensures rapid arc suppression.
  2. Customizable Ratings: Wide range of current/voltage configurations.
  3. Durability: Porcelain construction resists thermal and mechanical stress.
  4. Compliance: Meets IEC/ANSI standards for high-voltage protection.

Maintenance & Installation Tips

  • Inspection: Regularly check the indicator for fault alerts.
  • Replacement: Use identical-rated fuses to maintain system integrity.
  • Mounting: Follow dimensional charts (Tables 2-3) for precise alignment.

Conclusion

The RN1-10 High-Voltage Current Limiting Fuse combines cutting-edge engineering with robust materials to deliver unmatched protection for high-voltage systems. Its adaptability across voltages (3kV–35kV) and currents (7.5A–400A) makes it a universal solution for modern electrical infrastructure.

Optimize your system’s reliability today—contact us for pricing and technical support!

Contact Us


Fatal error: Uncaught ArgumentCountError: Too few arguments to function {closure}(), 1 passed in /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php on line 324 and exactly 2 expected in /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket-smart-preload/wp-rocket-smart-preload.php:629 Stack trace: #0 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(324): {closure}() #1 /www/wwwroot/lauramak.com/wp-includes/plugin.php(205): WP_Hook->apply_filters() #2 /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket/inc/Engine/Preload/Controller/CheckExcludedTrait.php(44): apply_filters() #3 /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket/inc/Engine/Preload/Subscriber.php(204): WP_Rocket\Engine\Preload\Subscriber->is_excluded_by_filter() #4 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(324): WP_Rocket\Engine\Preload\Subscriber->update_cache_row() #5 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(348): WP_Hook->apply_filters() #6 /www/wwwroot/lauramak.com/wp-includes/plugin.php(517): WP_Hook->do_action() #7 /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket/inc/Engine/Optimization/Buffer/Optimization.php(109): do_action() #8 [internal function]: WP_Rocket\Engine\Optimization\Buffer\Optimization->maybe_process_buffer() #9 /www/wwwroot/lauramak.com/wp-includes/functions.php(5471): ob_end_flush() #10 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(324): wp_ob_end_flush_all() #11 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(348): WP_Hook->apply_filters() #12 /www/wwwroot/lauramak.com/wp-includes/plugin.php(517): WP_Hook->do_action() #13 /www/wwwroot/lauramak.com/wp-includes/load.php(1304): do_action() #14 [internal function]: shutdown_action_hook() #15 {main} thrown in /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket-smart-preload/wp-rocket-smart-preload.php on line 629