TBB High Voltage Compensation Cabinet – Intelligent Reactive Power Management Solution for 6kV/10kV Systems

Table of Contents

Introduction to PINEELE TBB High Voltage Compensation Cabinet

The PINEELE TBB High Voltage Compensation Cabinet is a premium-grade solution designed for reactive power compensation in 6kV and 10kV power distribution systems. Developed with advanced modular design, intelligent protection systems, and international standards compliance, this High Voltage Compensation Cabinet ensures improved power factor, reduced energy loss, and increased operational stability across industrial, commercial, and infrastructure sectors.

Housed in a fully metal-clad enclosure, this all-in-one high voltage compensation solution integrates circuit breakers, capacitor banks, intelligent controllers, and metering devices for seamless performance. By employing either ABB VD4 or VS1 vacuum circuit breakers, and leveraging a compact yet robust architecture, the PINEELE compensation cabinet is ideal for medium-voltage reactive power regulation in modern smart grid systems.


Why Choose a PINEELE High Voltage Compensation Cabinet?

✅ Designed for Medium to High Voltage Grids

  • Rated up to 40.5kV, compatible with 6kV/10kV systems
  • Provides real-time compensation for reactive power loads

✅ Modular and Scalable

  • Fully all-packaged cabinet configuration with separate functional compartments
  • Scalable for different reactive power needs (1%–12% permittivity adjustable)

✅ Built for Safety and Reliability

  • Fail-safe interlocking, withdrawable units, and IP4X protection level
  • Fully enclosed design to prevent pest ingress and foreign object intrusion
TBB High Voltage Compensation Cabinet

Basic Specifications

ParameterValue
Model No.AC
CertificationISO9001
Shell MaterialSteel Plate
Voltage LevelHigh Voltage
InstallationRemovable
StructureCabinet
Current TypeAC
TypeDistribution Metering Box
FormAll-Packaged Type
Operation VoltageLow Voltage
SizeCustom Made
Protection ClassIP4X
Rated Control VoltageAC110V, 220V; DC110V, 220V
Rated System Voltage40.5kV
Rated Frequency50Hz
OriginJiangsu, China
TransportWooden Box
HS Code85372090

Technical Parameters Table

ProjectTechnical Parameters
Rated Voltage6kV / 10kV
1-Min Power Frequency Withstand Voltage23kV / 30kV
Auxiliary Control Circuit Withstand Voltage2000V
Rated Frequency50Hz
Protection ClassIP40
Permittivity Range1% – 12%

Structural Composition of the High Voltage Compensation Cabinet

The PINEELE High Voltage Compensation Cabinet is carefully engineered with several independently functioning compartments:

1. Circuit Breaker Section

  • Equipped with ABB VD4 or VS1 vacuum circuit breaker
  • Modular design ensures easy maintenance and high breaking capacity

2. Capacitor Bank Area

  • Uses dry-type capacitors configured in series-parallel networks
  • Real-time switching based on reactive load demands

3. Control and Monitoring Panel

  • Intelligent reactive power controller
  • Digital or analog meters, relay interfaces, optional touchscreen display

4. Cable Termination Compartment

  • Oversized junction box for complex industrial wiring
  • Convenient access design for inspection and maintenance

Advanced Functional Features

  • Reactive Power Compensation
    Automatically adjusts capacitor banks to maintain a stable power factor.
  • Energy Efficiency Optimization
    Reduces line loss and improves voltage stability across the network.
  • Built-in Intelligent Control
    Supports digital interfaces (MODBUS/RS485), remote monitoring, and fault alarms.
  • Structural Integrity & Durability
    Constructed with galvanized aluminum steel, rust-free and high-precision build.
  • Interlock Protection
    Prevents unsafe access or switching during operation.
  • Earthquake & Arc-Resistant
    Rigorously tested for fault containment and vibration resilience.

Application Benefits

Deploying a PINEELE High Voltage Compensation Cabinet offers:

  • Improved power factor (typically from 0.75 to >0.95)
  • Enhanced transformer and line load capacity
  • Reduced reactive energy bills
  • Increased safety and equipment protection
  • Smart grid integration readiness

Frequently Asked Questions (FAQs)

1. What is the function of a High Voltage Compensation Cabinet?

A High Voltage Compensation Cabinet improves power system efficiency by automatically compensating reactive power using capacitor banks. This reduces transformer load, lowers energy costs, and enhances voltage regulation.


2. Can the PINEELE cabinet be integrated with smart grid systems?

Yes, the PINEELE High Voltage Compensation Cabinet includes support for digital communication protocols, making it fully compatible with SCADA and IoT-based energy platforms.


3. Is the cabinet customizable for specific installation needs?

Absolutely. The cabinet can be tailored in terms of size, perm capacity, control voltage, breaker brand, and interface type to meet unique project requirements.


Real-World Applications

The PINEELE TBB High Voltage Compensation Cabinet is suitable for:

  • Heavy industries (steel, cement, chemical plants)
  • Semiconductor manufacturing
  • High-rise buildings and complexes
  • Data centers and IT parks
  • Transportation hubs and metro systems
  • Construction and tunnel projects
  • Power substations and transformer stations
  • Wind and solar renewable energy systems

Contact Us


Fatal error: Uncaught ArgumentCountError: Too few arguments to function {closure}(), 1 passed in /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php on line 324 and exactly 2 expected in /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket-smart-preload/wp-rocket-smart-preload.php:629 Stack trace: #0 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(324): {closure}() #1 /www/wwwroot/lauramak.com/wp-includes/plugin.php(205): WP_Hook->apply_filters() #2 /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket/inc/Engine/Preload/Controller/CheckExcludedTrait.php(44): apply_filters() #3 /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket/inc/Engine/Preload/Subscriber.php(204): WP_Rocket\Engine\Preload\Subscriber->is_excluded_by_filter() #4 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(324): WP_Rocket\Engine\Preload\Subscriber->update_cache_row() #5 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(348): WP_Hook->apply_filters() #6 /www/wwwroot/lauramak.com/wp-includes/plugin.php(517): WP_Hook->do_action() #7 /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket/inc/Engine/Optimization/Buffer/Optimization.php(109): do_action() #8 [internal function]: WP_Rocket\Engine\Optimization\Buffer\Optimization->maybe_process_buffer() #9 /www/wwwroot/lauramak.com/wp-includes/functions.php(5471): ob_end_flush() #10 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(324): wp_ob_end_flush_all() #11 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(348): WP_Hook->apply_filters() #12 /www/wwwroot/lauramak.com/wp-includes/plugin.php(517): WP_Hook->do_action() #13 /www/wwwroot/lauramak.com/wp-includes/load.php(1304): do_action() #14 [internal function]: shutdown_action_hook() #15 {main} thrown in /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket-smart-preload/wp-rocket-smart-preload.php on line 629