The CKJ5-125 Low Pressure AC Vacuum Contactor is a high-performance vacuum contactor engineered for long-distance switching and control of AC motors and circuits in power systems. With a rated Voltage guide of up to 1140V and a current capacity of 125A, this AC vacuum contactor excels in environments requiring frequent operations, such as industrial plants, mining, metallurgy, petrochemical facilities, power generation, and transportation networks.

CKJ5-125 Low Pressure AC Vacuum Contactor

Designed for durability and efficiency, the CKJ5-125 vacuum contactor is perfect for high-voltage solutions motor control, circuit protection, and managing power equipment in demanding applications, including explosion-proof settings when paired with electromagnetic starters.

Key Features of the CKJ5-125 AC Vacuum Contactor

  • Vacuum Arc Extinction: Reduces arc energy, minimizing wear and extending the lifespan of this AC vacuum contactor.
  • Compact & Robust Design: Built to withstand tough conditions while saving space.
  • High Electrical Endurance: Rated for over 60,000 electrical operations.
  • Versatile Applications: Ideal for mining, metallurgy, petrochemicals, and power systems.
  • Advanced Protection: Pair with thermal relays for thermal and electromagnetic safety.

Parameters & Technical Specifications

Product ModelRated Voltage (V)Rated Current (A)Main Contact ParameterPower Frequency Voltage Resistance (Effective Value)Opening Distance (mm)Over Travel (mm)Final Pressure (N)Main CircuitControl CircuitAuxiliary Circuit
CKJ5-80114036/110/220/380801.8 ± 0.230 ± 31 ± 0.24200250020002000
CKJ5-125114036/110/220/3801251.8 ± 0.230 ± 31 ± 0.24200250020002000
CKJ5-250114036/110/220/3802502 ± 0.278 ± 7.81 ± 0.24200250020002000
CKJ5-400114036/110/220/3804002 ± 0.2117.6 ± 11.81 ± 0.24200250020002000
CKJ5-600114036/110/220/3806002 ± 0.2196 ± 19.61 ± 0.24200250020002000

Additional Technical Parameters

Product ModelMaking Capacity (AC-3)Breaking Capacity (AC-4)Limit Breaking Current (A)Electric LifetimeMechanical LifetimeWeight
CKJ5-8010Ie, 100 Times8Ie, 25 Times2000, 3 Times60 × 10⁴6 × 10⁴4 KG
CKJ5-12510Ie, 100 Times8Ie, 25 Times2000, 3 Times60 × 10⁴6 × 10⁴4 KG
CKJ5-25010Ie, 100 Times8Ie, 25 Times4500, 3 Times60 × 10⁴6 × 10⁴8 KG
CKJ5-40010Ie, 100 Times8Ie, 25 Times4500, 3 Times60 × 10⁴2 × 10⁴12 KG
CKJ5-60010Ie, 100 Times8Ie, 25 Times6000, 3 Times60 × 10⁴0.5 × 10⁴20 KG

Installation & Dimensions

The CKJ5-125 AC Vacuum Contactor is designed for seamless integration into power systems. Its compact size ensures flexibility in installation:

  • Dimensions: 157mm x 134mm x 135mm
  • Installation Size: 142mm x 118mm (4–7mm bolts)

This vacuum contactor is easy to install, maintain, and replace, making it a practical choice for various setups.

Typical Applications of the CKJ5-125 Vacuum Contactor

  • AC Motor Control: Perfect for frequent motor startups and stops.
  • Industrial Power Equipment: Controls transformers, generators, and more.
  • Power Systems: Suited for medium- and low-voltage applications in energy, manufacturing, and processing industries.
  • Explosion-Proof Settings: Reliable in hazardous environments with proper safety integration.

Why Choose the CKJ5-125 AC Vacuum Contactor?

  1. Superior Reliability: Vacuum arc extinction ensures long life and low maintenance for this AC vacuum contactor.
  2. Broad Industry Use: Trusted in mining, petrochemicals, metallurgy, and power systems.
  3. Heavy-Duty Durability: Over 60,000 electrical operations for demanding tasks.
  4. Space-Saving Design: Compact yet powerful, ideal for constrained installations.
  5. Safety in Harsh Environments: Explosion-proof compatibility when paired with relays.

Frequently Asked Questions (FAQ)

1. What sets AC Vacuum Contactors apart from air contactors?

AC vacuum contactors like the CKJ5-125 use vacuum arc extinction for superior durability and reduced maintenance compared to air contactors, which suffer from faster wear and shorter lifespans.

2. How do I install the CKJ5-125 Vacuum Contactor?

This vacuum contactor is simple to install using the provided dimensions (142mm x 118mm). Ensure a dust-free, moisture-free environment and secure main and auxiliary circuit connections.

3. Which industries benefit from the CKJ5-125 AC Vacuum Contactor?

Mining, petrochemical, metallurgy, energy, and transportation sectors rely on this AC vacuum contactor for its reliability and performance in high-voltage, frequent-switching tasks.

Contact Us


Fatal error: Uncaught ArgumentCountError: Too few arguments to function {closure}(), 1 passed in /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php on line 324 and exactly 2 expected in /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket-smart-preload/wp-rocket-smart-preload.php:629 Stack trace: #0 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(324): {closure}() #1 /www/wwwroot/lauramak.com/wp-includes/plugin.php(205): WP_Hook->apply_filters() #2 /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket/inc/Engine/Preload/Controller/CheckExcludedTrait.php(44): apply_filters() #3 /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket/inc/Engine/Preload/Subscriber.php(204): WP_Rocket\Engine\Preload\Subscriber->is_excluded_by_filter() #4 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(324): WP_Rocket\Engine\Preload\Subscriber->update_cache_row() #5 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(348): WP_Hook->apply_filters() #6 /www/wwwroot/lauramak.com/wp-includes/plugin.php(517): WP_Hook->do_action() #7 /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket/inc/Engine/Optimization/Buffer/Optimization.php(109): do_action() #8 [internal function]: WP_Rocket\Engine\Optimization\Buffer\Optimization->maybe_process_buffer() #9 /www/wwwroot/lauramak.com/wp-includes/functions.php(5471): ob_end_flush() #10 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(324): wp_ob_end_flush_all() #11 /www/wwwroot/lauramak.com/wp-includes/class-wp-hook.php(348): WP_Hook->apply_filters() #12 /www/wwwroot/lauramak.com/wp-includes/plugin.php(517): WP_Hook->do_action() #13 /www/wwwroot/lauramak.com/wp-includes/load.php(1304): do_action() #14 [internal function]: shutdown_action_hook() #15 {main} thrown in /www/wwwroot/lauramak.com/wp-content/plugins/wp-rocket-smart-preload/wp-rocket-smart-preload.php on line 629